Steel fire shutter door rated to UL 10B with a 180-minute fire-resistance rating, for fire compartmentation in industrial, commercial and public buildings.

Key specifications

  • Fire Resistance Rating: 180 min (3 h)
  • Opening Speed: 0.1 m/s
  • Closing Speed: 0.1 m/s
  • Safety Devices: Thermal Release Device / Smoke & Heat Detector (Optional)
  • Control Methods: Push Button / Fire Alarm Interlock
Fire resistance, rated to UL 10B
180 min (3h)
Opening and closing speed
0.1m/s
PPS 100 curtain slat (standard)
1.5mm
Aluminum-zinc coated steel guide rail (standard)
2.0mm

Product details

The UL steel fire roller shutter door is rated to UL 10B, with a fire-resistance rating of 180 minutes. It is used for fire compartmentation in industrial, commercial and public buildings.

Specifications

UL Steel Fire Shutter Door: Specifications
Fire Resistance Rating180 min (3 h)
Installation OptionsInside Mount / Side Mount
Opening Speed0.1 m/s
Closing Speed0.1 m/s
Safety DevicesThermal Release Device / Smoke & Heat Detector (Optional)
Control MethodsPush Button / Fire Alarm Interlock

Standards & ratings

Rating as stated in the CUBIXY product catalogue. The certificates are held by our partner manufacturer.

  • UL 10B180 min

    Fire resistance

    Rated to UL 10B, the UL fire test for door assemblies, with a fire-resistance rating of 180 minutes (3 hours).

    Certificate

    Certificate documents pending

Options & configuration

Standard configuration

  • PPS 100 1.5 mm steel curtain slat

    Curtain Slat: PPS 100 1.5 mm

  • Guide rail, 2.0 mm galvanized / stainless steel

    Guide Rail: 2.0 mm Aluminum-Zinc Coated Steel

Frequently Asked Questions

What fire rating does the UL steel fire shutter have?
It is rated to UL 10B with a fire-resistance rating of 180 minutes.
What is the standard configuration?
A PPS 100 curtain slat in 1.5 mm and a 2.0 mm aluminum-zinc coated steel guide rail. It can be inside-mounted or side-mounted.
How is the UL fire shutter operated?
By push button or fire alarm interlock, at 0.1 m/s opening and closing speed, with a thermal release device and optional smoke and heat detectors.

Ask about UL Steel Fire Shutter Door

Tell us the opening size (W × H), door type, application, performance requirements (fire, wind, insulation), control method, quantity and project location. We reply by email with a specification and quotation.

Opening size (W × H), door type, application, performance requirements, control method, quantity and project location. Include whatever details you already have.

We use your details only to reply to this enquiry.

Contact information